Best Seller

Delta DOP-100 Standard DOP-107CV 7-inch Touch HMI

DOP-107CV is a Delta DOP-100 Standard HMI 7-inch touch hmi with 800 × 480 pixel TFT LCD display. It operates on 24V DC and provides RS-232, RS-422, RS-485; USB Host × 1, USB Client × 1. Project configuration uses DOPSoft 4.0. Suitable for operator visualization with compatible external controllers.

ModelDOP-107CV
Warranty12 Months

Price (incl. VAT)

BrandDelta
SeriesDOP-100
ModelDOP-107CV
Part NoDOP-107CV
HMI TypeTouch HMI
Display Size7 in
Display Resolution800 × 480 px
Display TechnologyTFT LCD
Input TypeResistive touch
Program Memory256 MB
Memory Card SupportNo
Programming SoftwareDOPSoft 4.0
Communication PortsRS-232, RS-422, RS-485, USB
Built-in Communication ProtocolsDelta Controller
PLC CompatibilityDelta Controllers, Serial Communication
Power Supply24V DC
Dimension215 × 161 × 61.2 mm
Panel Cutout Dimensions196.9 × 142.9 mm
Product Weight970 g
Mounting OrientationLandscape
Protection RatingIP65, NEMA 4, UL Type 4X
Warranty12 Months

Delta DOP-100 Standard DOP-107CV 7-inch Touch HMI

DOP-107CV is the 7 inch DOP-100 Standard HMI operator panel identified in this listing. Its purpose is to let personnel inspect machine status, enter setpoints, acknowledge operator messages and interact with a correctly configured industrial control system. It is an HMI interface, not a standalone PLC or an industrial panel computer. The selected order code is important: a display size, communication connector or hardware suffix from another Delta model must not be used as a substitute when preparing a project, purchasing a replacement, or machining an enclosure.

Display and Operator Interface

The 7 inch TFT LCD screen has native resolution 800 × 480 pixels. Native resolution describes the HMI’s own display rather than a monitor connected through an external interface. Operator entry uses resistive touch, which is suitable for on-screen buttons, menus and numerical entries created in a compatible project. Display elements should be sized for the actual panel and tested using the selected model in the editor. A different screen diagonal or pixel matrix can change text layout and control positioning even within one product family.

Communication and PLC Compatibility

Physical interfaces documented for this listing are RS-232, RS-422, RS-485; USB Host × 1, USB Client × 1. Physical ports must not be confused with installed communication drivers or active protocols. The specification value for protocols is Delta Controller ASCII / RTU, and controller compatibility is recorded as Delta DVP-series PLC, Serial Communication. Driver selection, station numbering, cable pinout, serial framing and any Ethernet connection must match the specific PLC or automation device. Where no Ethernet connector is listed, do not design an installation that depends on direct LAN connection.

Programming and Runtime Functions

HMI projects are prepared using DOPSoft 4.0. A project should begin with the exact device selection and its actual communication settings, followed by screen objects, navigation, messages and the appropriate controller addresses. Delta’s DOP-100 software documentation covers visual elements, alarms, recipes and user-management features at family level. Availability of a particular runtime feature should be confirmed in the exact project and firmware. Never treat a network connector as proof that a particular remote protocol is active.

Memory and Storage

The displayed Program Memory field is 256 MB. For this HMI it reflects documented total internal Flash ROM capacity; it is not a separate verification of how much space is available to the user project. Memory-card support is listed as No. A USB connection, when present, must not be described as an SD-card slot. Runtime records and historical data should be planned against the actual firmware functions and available storage.

Installation and Typical Applications

The rated power entry is 24V DC. The reported external dimensions are 215 × 161 × 61.2 mm (width × height × depth). The listed panel opening is 196.9 × 142.9 mm (width × height). Protection is recorded as IP65 / NEMA 4 / UL Type 4X (Front); this should not be interpreted as proof that every exposed connector or rear surface has the same ingress rating. Use the specified fasteners, grounding and panel gasket conditions in the installation guide. Before manufacturing the cabinet, verify the drawing revision, mounting thickness, ventilation clearance and cable bend radius.

Exact Variant Verification

This entry identifies the Standard General variant, not every product in DOP-100 Standard HMI. The installed model number should match DOP-107CV exactly. The different Basic, Standard, Ethernet, Advanced and Multimedia codes can change port counts, SD support, housing dimensions and screen resolution. If an identified feature is not verified in the source notes, leave it open rather than copying a specification from a similarly named device.

Engineering Integration Checklist

For commissioning, first confirm the unit’s actual nameplate and hardware revision. Prepare a supported power supply and grounding scheme, and verify the display orientation and clearance against the correct mechanical drawing. In the HMI project, choose the device and communication driver deliberately, confirm baud rate or IP addressing, and test reading and writing one safe controller tag before connecting wider machine functions. Store a backup of the accepted project and record the firmware and editor versions. Operator controls should be designed as part of the wider machine safeguarding strategy; an ordinary HMI touch button does not replace a certified emergency-stop circuit or a safety controller.

Official Manufacturer Links

Official Manufacturer Product Page Link:

Official Manufacturer Datasheet / Technical Documentation Link:

Similar Products

DOP-100 Series Products

  • 7 in TFT LCD, 800 × 480 px
  • Resistive Touch operator entry
  • 24V DC rated supply
  • RS-232, RS-422, RS-485; USB Host × 1, USB Client × 1
  • HMI software: DOPSoft 4.0
  • No memory-card support
  • IP65 / NEMA 4 / UL Type 4X (Front)
  • PLC-based machine operation and setpoint entry
  • Production equipment status visualization
  • Motor drive and automation parameter monitoring
  • Operator alarm and event display
  • Control panel integration and local maintenance
  • Process adjustment with compatible Delta controllers

Reviews

There are no reviews yet.

Be the first to review “Delta DOP-100 Standard DOP-107CV 7-inch Touch HMI”

Your email address will not be published. Required fields are marked *

This is shipping and returns content

Need Help Choosing?

Our automation experts are ready to help you select the right product for your application.

  • Application Consultation
  • Product Selection Support
  • Wiring & Integration Help
  • After Sales Support
Chat on WhatsApp

+880 1553-346553