| Brand | Delta |
|---|---|
| Series | DOP-100L |
| Model | DOP-107L2-01 |
| Part No | DOP-107L2-01 |
| HMI Type | Touch HMI |
| Display Size | 7″ |
| Display Resolution | 1024 × 600 px |
| Display Technology | IPS TFT LCD |
| Input Type | Resistive touch |
| Program Memory | 256 MB |
| Memory Card Support | Not Verified |
| Programming Software | DIAScreen |
| Communication Ports | Ethernet, RS-232, RS-422, RS-485, USB Type-A |
| Built-in Communication Protocols | MQTT, OPC UA |
| PLC Compatibility | Delta Controllers, Serial Communication |
| Power Supply | 24V DC |
| Panel Cutout Dimensions | 192 × 138 mm |
| Product Weight | 536 g |
| Mounting Orientation | Landscape |
| Protection Rating | IP66 |
| Warranty | 12 Months |
Delta DOP-100L DOP-107L2-01 7-inch IPS Touch HMI
DOP-107L2-01 is the 7 inch DOP-100L operator panel identified in this listing. Its purpose is to let personnel inspect machine status, enter setpoints, acknowledge operator messages and interact with a correctly configured industrial control system. It is an HMI interface, not a standalone PLC or an industrial panel computer. The selected order code is important: a display size, communication connector or hardware suffix from another Delta model must not be used as a substitute when preparing a project, purchasing a replacement, or machining an enclosure.
Display and Operator Interface
The 7 inch IPS TFT LCD screen has native resolution 1024 × 600 pixels. Native resolution describes the HMI’s own display rather than a monitor connected through an external interface. Exact-model distributor information identifies four-wire resistive touch for this L2 variant; verify the manufacturer’s hardware revision. Display elements should be sized for the actual panel and tested using the selected model in the editor. A different screen diagonal or pixel matrix can change text layout and control positioning even within one product family.
Communication and PLC Compatibility
Physical interfaces documented for this listing are RS-232, RS-422, RS-485; Ethernet × 1; USB. Physical ports must not be confused with installed communication drivers or active protocols. Delta’s official L Type product information documents MQTT and OPC UA Client. The serial port also permits communication with compatible Delta DVP-series PLCs; verify the configured driver, cable and firmware before commissioning. Network connectivity does not automatically enable cloud services, remote viewing or third-party protocols.
Programming and Runtime Functions
Delta’s DIAScreen editor is used for DOP-100 family HMI projects. Verify the supported editor release and firmware combination for this exact L Type variant before deployment. A project should begin with the exact device selection and its actual communication settings, followed by screen objects, navigation, messages and the appropriate controller addresses. Delta’s DOP-100 software documentation covers visual elements, alarms, recipes and user-management features at family level. Availability of a particular runtime feature should be confirmed in the exact project and firmware. Never treat a network connector as proof that a particular remote protocol is active.
Memory and Storage
The displayed Program Memory field is 256 MB. For this HMI it reflects documented total internal Flash ROM capacity; it is not a separate verification of how much space is available to the user project. An SD-card slot has not been confirmed for the L2 model. Do not assume removable SD storage is present. Runtime records and historical data should be planned against the actual firmware functions and available storage.
Installation and Typical Applications
The rated power entry is 24V DC. The overall external size has not yet been confirmed from an exact-model manufacturer drawing. The listed panel opening is 192 × 138 mm (width × height). Protection is recorded as IP66 (Front; distributor stated); this should not be interpreted as proof that every exposed connector or rear surface has the same ingress rating. Use the specified fasteners, grounding and panel gasket conditions in the installation guide. Before manufacturing the cabinet, verify the drawing revision, mounting thickness, ventilation clearance and cable bend radius.
Exact Variant Verification
This entry identifies the Lite L2 variant, not every product in DOP-100L. The installed model number should match DOP-107L2-01 exactly. Lite L1 and L2 models have different published panel openings even at the same nominal screen size. A distributor listing is not enough for final mechanical design without the manufacturer’s drawing. If an identified feature is not verified in the source notes, leave it open rather than copying a specification from a similarly named device.
Engineering Integration Checklist
For commissioning, first confirm the unit’s actual nameplate and hardware revision. Prepare a supported power supply and grounding scheme, and verify the display orientation and clearance against the correct mechanical drawing. In the HMI project, choose the device and communication driver deliberately, confirm baud rate or IP addressing, and test reading and writing one safe controller tag before connecting wider machine functions. Store a backup of the accepted project and record the firmware and editor versions. Operator controls should be designed as part of the wider machine safeguarding strategy; an ordinary HMI touch button does not replace a certified emergency-stop circuit or a safety controller.
Official Manufacturer Links
Official Manufacturer Product Page (series-level): https://www.delta-china.com.cn/zh-CN/products/Touch-Panel-HMI-Human-Machine-Interfaces/L-Type
Official Manufacturer Datasheet / Technical Documentation: Delta L Type official overview: https://www.delta-china.com.cn/zh-CN/products/Touch-Panel-HMI-Human-Machine-Interfaces/L-Type (exact L2 drawing not found)
Additional model-specific distributor information: https://www.es.co.th/detail.asp?Prod=029006508
Suggested Internal Link
Suggested Internal Link: Add a link to the relevant Delta brand, HMI series or industrial HMI category page on the PLC Store BD website.
• 7 in IPS TFT LCD, 1024 × 600 px
• Resistive Touch input
• 24V DC supply
• RS-232, RS-422, RS-485; Ethernet × 1; USB Host
• MQTT and OPC UA Client (L Type family)
• DIAScreen programming software
• L2 mounting opening; confirm exact housing drawing
• IP66 front (manufacturer L1 / family documentation)
• PLC-based machine operation and setpoint entry
• Production equipment status visualization
• Motor drive and automation parameter monitoring
• Operator alarm and event display
• Control panel integration and local maintenance
• Process adjustment with compatible Delta controllers
Need Help Choosing?
Our automation experts are ready to help you select the right product for your application.
- Application Consultation
- Product Selection Support
- Wiring & Integration Help
- After Sales Support
Chat on WhatsApp
+880 1553-346553















Reviews
There are no reviews yet.