Siemens SINAMICS V20 7.5 kW 3-Phase VFD 6SL3210-5BE27-5UV1
The Siemens SINAMICS V20 6SL3210-5BE27-5UV1 is a 7.5 kW (10 HP) VFD for three-phase 380–480 V AC input, delivering 16.50 A rated output. It supports USS and Modbus RTU, features an integrated braking chopper, and has an unfiltered EMC configuration. The IP20 converter uses a compact FSC frame.
| Model | SINAMICS V20 7.5 kW, 3AC, FSC, unfiltered |
|---|
| Brand | Siemens |
|---|---|
| Series | SINAMICS V20 |
| Model | SINAMICS V20 7.5 kW, 3AC, FSC, unfiltered |
| Part No | 6SL3210-5BE27-5UV1 |
| Rated Motor Power | 7.50 kW / 10.00 HP |
| Input Phase | Three Phase (3P AC) |
| Input Voltage | 380–480 V AC |
| Output Voltage | 3P AC; 400 V IEC nominal / 480 V NEC |
| Rated Output Current | 16.50 A |
| Output Frequency | 0–550 Hz |
| Control Mode | Variable-speed control for three-phase asynchronous motors |
| Duty Rating / Overload Capacity | LO: 110% × 60 s / 300 s cycle; HO: 150% × 60 s / 300 s cycle |
| Built in Communication | USS and Modbus RTU over RS-485 |
| EMC Filter | Unfiltered |
| Braking Configuration | Built-in brake chopper |
| Protection Rating | IP20 / UL open type |
| Supported Motor Types | 3 Phase Asynchronous (Induction) Motors |
| Keypad / Operator Panel | Built-in Basic Operator Panel (BOP) |
| Dimensions (W × H × D) | 184 × 182 × 169 mm |
Siemens SINAMICS V20 7.5 kW 3-Phase VFD 6SL3210-5BE27-5UV1
Overview
6SL3210-5BE27-5UV1 is a Siemens SINAMICS V20 variable frequency drive (VFD) designed for adjustable-speed operation of suitable three-phase AC motors. It is a 7.5 kW, 10 HP-rated converter for three-phase 380–480 V AC mains. The manufacturer specifies the same 7.50 kW rating for Low Overload (LO) and High Overload (HO) operation. Its nominal output current is 16.50 A under both duty classifications. The exact suffix UV1 matters: this version is supplied without an integrated EMC filter and incorporates an integrated braking chopper. It is not the older UV0 unit, even though both share the same power rating.
Electrical Ratings
The converter accepts three-phase 380–480 V AC supply with Siemens-stated tolerance of −15%/+10%, at 47–63 Hz input frequency. Its output is three-phase AC, with 400 V IEC and 480 V NEC reference ratings. Siemens quotes 7.50 kW / 10.00 HP for both LO and HO duty and 16.50 A continuous output current for either duty classification; the HP and output-current data for the 480 V NEC basis are applicable at 440–480 V. The adjustable output frequency is 0–550 Hz. This is a converter output capability, not a declaration that every connected motor can operate safely over that full range. Motor sizing must take nameplate current, load torque and thermal conditions into account.
Control Modes and Overload Performance
The SINAMICS V20 family provides adjustable motor-speed and torque management through its documented inverter control functions. Control-mode selection and motor data should be checked in the Siemens operating instructions for the particular connected motor and application. Siemens specifies 110% of rated current for 60 seconds in Low Overload mode, with a 300-second cycle. In High Overload mode it specifies 150% for 60 seconds, also on a 300-second cycle. Because each mode has its own time and duty basis, an overload percentage is not a continuous rating. Application suitability should be evaluated against starting requirements, load inertia, acceleration time and duty cycle.
Communication and Configuration
The exact Siemens datasheet lists USS and Modbus RTU communication. These are communication protocols, not evidence of an integrated Ethernet port. The SINAMICS V20 has a built-in Basic Operator Panel (BOP) for local parameter setting and operation, as stated in Siemens product literature. The datasheet lists four standard digital inputs, one relay changeover output, one transistor output, two analog inputs and one analog output. The analog inputs may also serve as additional digital inputs, subject to configuration. Any external adapters, communications interfaces or option modules must be selected separately and cannot be assumed included.
EMC, Braking and Built-in Functions
For 6SL3210-5BE27-5UV1, Siemens explicitly specifies an unfiltered EMC configuration. Where an installation has defined electromagnetic-compatibility obligations, an appropriately selected external filter and compliant cable and grounding practices may be necessary. The same datasheet explicitly states that an integrated braking chopper is present. A chopper is not an included braking resistor: external braking resistance, sizing, wiring and permitted duty must be evaluated using Siemens documentation. The manufacturer lists a 4.00 kHz nominal pulse frequency, which may be subject to settings and derating. Do not substitute the integrated chopper rating for a complete braking design.
Installation and Environmental Conditions
This model uses the compact FSC frame with Siemens-published dimensions of 184.0 mm wide, 182.0 mm high and 169.0 mm deep. It is rated IP20 / UL open type, so the installation must provide suitable protection against dust, moisture, accidental contact and other site hazards. The exact datasheet identifies wall, through-hole and side-by-side mounting options, and states convection cooling. It gives 1,000 m as the reference installation altitude and an operating temperature range of −10 to 60 °C, subject to derating from 40 °C upward. Published cable-length guidance is 10 m shielded and 50 m unshielded; consult the relevant filter and EMC provisions for real installations. Respect ventilation, mounting orientation, protective earthing and circuit-protection requirements in the operating instructions.
Applications and Selection Guidance
The V20 series is suitable for straightforward adjustable-speed tasks where the motor and mechanical system are compatible. Examples include appropriately sized pumps, fans, conveyors, mixers and general machine drives; these are application suggestions rather than a guarantee of fit. Select by rated current as well as nominal motor kW, voltage, acceleration requirements and load behavior. Applications with rapid stopping, overhauling loads or high inertia may require a correctly sized external braking resistor. The unfiltered design means compliance planning may require external EMC components. Confirm that any motor, machine or electrical installation operates within its approved speed and thermal limits.
Exact Variant Verification
The supplied part number is 6SL3210-5BE27-5UV1. It belongs to the 380–480 V three-phase SINAMICS V20 group and has the FSC enclosure measuring 184 × 182 × 169 mm. It must not be confused with the older 6SL3210-5BE27-5UV0, whose frame is FSD and larger, or with filtered 6SL3210-5BE27-5CV1. Siemens documents integrated braking hardware on this UV1 variant, but no integrated EMC filter. Before replacing an existing drive, verify terminal layout, installation clearances, external components, selected parameters, motor protection and other system-specific conditions. Do not infer mechanical interchangeability solely from shared kW ratings.
Official Manufacturer Links
Official Manufacturer Product Page: https://mall.industry.siemens.com/mall/en/WW/Catalog/Product/6SL3210-5BE27-5UV1
Official Manufacturer Datasheet / Technical Documentation: https://mall.industry.siemens.com/spice/docuservice/docuservice?configid=14&docu.mlfb=6SL3210-5BE27-5UV1&docu.inittype=MLFB&docu.generationtype=VIEW&docu.viewid=PDF®ion=AE&language=en&docu.language.locale1=en&docu.language.locale2=en
Official Operating Instructions: https://support.industry.siemens.com/cs/attachments/109977897/V20_op_instr_1224_en-US.pdf
Similar Products
SINAMICS V20 VFD:https://plcstorebd.com/product-category/vfd/siemens-vfd/
• 7.50 kW / 10 HP SINAMICS V20 AC drive for three-phase supply
• 380–480 V AC three-phase input (−15%/+10%)
• 16.50 A rated continuous output at the specified voltage/duty basis
• LO 110% / 60 s and HO 150% / 60 s; 300 s cycle each
• USS and Modbus RTU communication
• Integrated braking chopper; resistor selected separately
• Unfiltered EMC configuration; external filtering if required
• IP20 / UL open type with FSC 184 × 182 × 169 mm frame
• Variable-speed pumps with compatible motor and hydraulic duty
• Ventilation and exhaust fans sized to 16.50 A output
• Conveyor drives within motor and mechanical ratings
• Process mixers with appropriate torque and overload assessment
• General machine speed control using a suitable three-phase AC motor
• Material-handling drives after starting and stopping duty review
• Inertia loads where separately selected braking resistance is required
• Panel-based industrial motor-speed control with compliant EMC design
Need Help Choosing?
Our automation experts are ready to help you select the right product for your application.
- Application Consultation
- Product Selection Support
- Wiring & Integration Help
- After Sales Support
Chat on WhatsApp
+880 1553-346553















Reviews
There are no reviews yet.