Best Seller

Siemens SINAMICS V20 6SL3210-5BE13-7CV1 0.37 kW 3-Phase VFD

Siemens SINAMICS V20 6SL3210-5BE13-7CV1 is a 0.37 kW, three-phase 380–480 V AC variable frequency drive rated at 1.30 A. This filtered CV1 variant includes C3 EMC filtering, built-in USS/Modbus RTU communication, a Basic Operator Panel and an integrated braking unit. Its FSA enclosure has an IP20 protection rating.

ModelSINAMICS V20, 0.37 kW, 3 AC, filtered CV1

TBA

Price (incl. VAT)

BrandSiemens
SeriesSINAMICS V20
ModelSINAMICS V20, 0.37 kW, 3 AC, filtered CV1
Part No6SL3210-5BE13-7CV1
Rated Motor Power0.37 kW
Input PhaseThree Phase (3P AC)
Input Voltage380–480 V AC
Output Voltage3P AC; 400 V IEC nominal / 480 V NEC
Rated Output Current1.30 A
Output Frequency0–550 Hz
Control ModeV/f control (confirm firmware-specific supported modes in Siemens operating instructions)
Duty Rating / Overload CapacityHO: 150% for 60 s / 300 s cycle; LO: 110% for 60 s / 300 s cycle
Built in CommunicationUSS and Modbus RTU over RS-485
EMC FilterNo built-in EMC filter
Protection RatingIP20 / UL open type
Supported Motor Types3 Phase Asynchronous (Induction) Motors
Keypad / Operator PanelBuilt-in Basic Operator Panel (BOP)
Dimensions (W × H × D)90 × 150 × 145.5 mm

Siemens SINAMICS V20 6SL3210-5BE13-7CV1 0.37 kW 3-Phase VFD

Product identity

The 6SL3210-5BE13-7CV1 is a Siemens SINAMICS V20 basic AC drive designed for speed control of a compatible three-phase AC motor. This exact CV1 order number denotes the 0.37 kW filtered version in frame size FSA. Its manufacturer specification identifies a three-phase 380–480 V AC line supply, an integrated C3 EMC filter and an integrated braking unit. These configuration details are important when selecting a drive for a panel, a replacement installation or a new machine.

Electrical Ratings

The converter has a rated motor power of 0.37 kW and a rated output current of 1.30 A. Siemens lists three-phase input, a nominal line voltage range of 380–480 V AC with −15%/+10% tolerance and an input frequency of 47–63 Hz. Output is three-phase variable-frequency AC for a suitably rated motor. The V20 documentation specifies a 0–550 Hz output-frequency range; maximum drive frequency is not a claim that every connected motor or machine may safely run at that speed. Select the motor using its nameplate voltage and current, not the power figure alone.

Control Modes and Performance

Siemens lists 150% overload for 60 seconds for this order number. Its V20 documentation distinguishes high-overload and low-overload operating modes; it also documents 110% for 60 seconds in low-overload mode, with a 300-second cycle. Preserve those operating-mode and timing conditions when selecting a drive. SINAMICS V20 offers V/f-based speed control, including characteristic options described in the manufacturer operating instructions. Motor starting, acceleration, braking and steady-state performance depend on parameter settings, motor characteristics and the driven equipment.

Communication and Configuration

Built-in USS and Modbus RTU fieldbus support are identified by Siemens. The presence of a physical connector must not be interpreted as Ethernet or other network protocol support. A built-in Basic Operator Panel (BOP) supports local setup and operation. The manufacturer lists four digital inputs, two digital outputs, two analog inputs and one analog output for this variant. Parameter setup and communication integration should follow the Siemens V20 operating instructions and the selected controller communication configuration.

EMC Filter and Braking

The CV1 variant has an integrated C3 EMC filter, unlike the unfiltered UV1 version. C3 is an EMC category and does not guarantee compliant installation on its own: grounding, cable routing, shielding and installation conditions remain significant. Siemens specifically lists an integrated braking unit for this CV1 revision. This is a hardware distinction from the older CV0 variant. An external braking resistor must be chosen in accordance with applicable Siemens documentation and is not confirmed as included with the drive. The integrated unit must not be equated with an included external resistor.

Installation and Protection

The drive is IP20 / UL open type, frame size FSA. Siemens specifies dimensions of 90 × 150 × 145.5 mm (W × H × D). Its operating instructions describe wall and side-by-side mounting, convection cooling for this low-power frame, installation clearances and environmental limitations. Rated operation requires attention to ambient temperature, enclosure ventilation, line conditions, permissible motor cable length, protective devices and installation altitude. IP20 does not make the unit suitable for exposed outdoor, wet or dusty locations without suitable enclosure protection.

Applications

The 0.37 kW rating makes the drive relevant to small, compatible three-phase motor systems, such as light-duty conveyors, small fans, small pumps and variable-speed auxiliary machinery, subject to checking motor current, starting torque, duty profile and protective arrangements. Braking requirements must be checked against the load inertia and permitted braking hardware. Selection is based on actual duty and the official motor/drive ratings; these examples are technically suitable possibilities rather than guarantees of universal compatibility.

Exact Variant Verification

This workbook covers 6SL3210-5BE13-7CV1, not the older 6SL3210-5BE13-7CV0 or the unfiltered 6SL3210-5BE13-7UV1. Siemens identifies the CV1 as filtered (C3) and equipped with an integrated braking unit. The old CV0 must not be assumed to contain the same braking hardware. Siemens’ product listing identifies the CV1 as an active product at research time. Manufacturer descriptions and datasheets are the controlling sources if distributor information differs.

Official Manufacturer Links

Official Manufacturer Product Page: https://sieportal.siemens.com/en-us/products-services/detail/6SL32105BE137CV1

Official Manufacturer Datasheet / Technical Documentation: https://mall.industry.siemens.com/mall/en/en/Catalog/Product/6SL32105BE137CV1

Official Operating Instructions: https://support.industry.siemens.com/cs/attachments/109977897/V20_op_instr_1224_en-US.pdf

 

Similar Products

SINAMICS V20 VFD:https://plcstorebd.com/product-category/vfd/siemens-vfd/

• 0.37 kW Siemens SINAMICS V20, exact CV1 variant
• Three-phase 380–480 V AC input, −15%/+10% tolerance
• 1.30 A rated three-phase output current
• High overload 150% for 60 s; low overload 110% for 60 s
• Built-in USS / Modbus RTU communication and BOP
• Integrated C3 EMC filter
• Integrated braking unit; resistor not confirmed included
• IP20 / UL open-type FSA enclosure

• Small conveyors with compatible three-phase motors
• Small fans requiring adjustable speed
• Small centrifugal pumps within rated motor current
• Packaging machine auxiliary drives
• Small material-handling equipment
• Process equipment requiring variable speed
• Small machine retrofit where supply and EMC conditions match

Reviews

There are no reviews yet.

Be the first to review “Siemens SINAMICS V20 6SL3210-5BE13-7CV1 0.37 kW 3-Phase VFD”

Your email address will not be published. Required fields are marked *

This is shipping and returns content

Need Help Choosing?

Our automation experts are ready to help you select the right product for your application.

  • Application Consultation
  • Product Selection Support
  • Wiring & Integration Help
  • After Sales Support
Chat on WhatsApp

+880 1553-346553