Delta DOP-100L DOP-107L1-01 7-inch IPS Touch HMI
DOP-107L1-01 is a Delta DOP-100L 7-inch IPS TFT LCD touch HMI (1024 × 600 px) with resistive input and 24V DC supply. It provides RS-232, RS-422, RS-485 and Ethernet connectivity. The L Type family supports MQTT and OPC UA Client; configure using DIAScreen and a compatible controller driver.
| Model | DOP-107L1-01 |
|---|---|
| Warranty | 12 Months |
| Brand | Delta |
|---|---|
| Series | DOP-100L |
| Model | DOP-107L1-01 |
| Part No | DOP-107L1-01 |
| HMI Type | Touch HMI |
| Display Size | 7″ |
| Display Resolution | 1024 × 600 px |
| Input Type | Resistive touch |
| Program Memory | 256 MB |
| Memory Card Support | No |
| Programming Software | DIAScreen |
| Communication Ports | Ethernet, RS-232, RS-422, RS-485, USB Type-A |
| Built-in Communication Protocols | MQTT, OPC UA |
| PLC Compatibility | Delta Controllers, Serial Communication |
| Power Supply | 24V DC |
| Dimensions (W × H × D) | 208.7 × 154.7 × 40.8 mm |
| Mounting Orientation | Landscape |
| Protection Rating | IP66 |
| Warranty | 12 Months |
Delta DOP-100L DOP-107L1-01 7-inch IPS Touch HMI
DOP-107L1-01 is the 7 inch DOP-100L operator panel identified in this listing. Its purpose is to let personnel inspect machine status, enter setpoints, acknowledge operator messages and interact with a correctly configured industrial control system. It is an HMI interface, not a standalone PLC or an industrial panel computer. The selected order code is important: a display size, communication connector or hardware suffix from another Delta model must not be used as a substitute when preparing a project, purchasing a replacement, or machining an enclosure.
Display and Operator Interface
The 7 inch IPS TFT LCD screen has native resolution 1024 × 600 pixels. Native resolution describes the HMI’s own display rather than a monitor connected through an external interface. Delta’s 2026 model-specific L1 installation instructions specify a four-wire resistive touchscreen. Display elements should be sized for the actual panel and tested using the selected model in the editor. A different screen diagonal or pixel matrix can change text layout and control positioning even within one product family.
Communication and PLC Compatibility
Physical interfaces documented for this listing are RS-232, RS-422, RS-485; Ethernet × 1; USB. Physical ports must not be confused with installed communication drivers or active protocols. Delta’s official L Type product information documents MQTT and OPC UA Client. The serial port also permits communication with compatible Delta DVP-series PLCs; verify the configured driver, cable and firmware before commissioning. Network connectivity does not automatically enable cloud services, remote viewing or third-party protocols.
Programming and Runtime Functions
Delta’s DIAScreen editor is used for DOP-100 family HMI projects. Verify the supported editor release and firmware combination for this exact L Type variant before deployment. A project should begin with the exact device selection and its actual communication settings, followed by screen objects, navigation, messages and the appropriate controller addresses. Delta’s DOP-100 software documentation covers visual elements, alarms, recipes and user-management features at family level. Availability of a particular runtime feature should be confirmed in the exact project and firmware. Never treat a network connector as proof that a particular remote protocol is active.
Memory and Storage
The displayed Program Memory field is 256 MB. For this HMI it reflects documented total internal Flash ROM capacity; it is not a separate verification of how much space is available to the user project. The 2026 exact-model Delta L1 installation sheet lists SD support as unavailable. Do not plan to use an SD card slot for backups. Runtime records and historical data should be planned against the actual firmware functions and available storage.
Installation and Typical Applications
The rated power entry is 24V DC. Delta’s model-specific L1 installation drawing specifies external dimensions 208.7 × 154.7 × 40.8 mm (width × height × depth). The listed panel opening is 196.9 × 142.9 mm (width × height). Protection is recorded as IP66 (Front; distributor stated); this should not be interpreted as proof that every exposed connector or rear surface has the same ingress rating. Use the specified fasteners, grounding and panel gasket conditions in the installation guide. Before manufacturing the cabinet, verify the drawing revision, mounting thickness, ventilation clearance and cable bend radius.
Exact Variant Verification
This entry identifies the Lite L1 variant, not every product in DOP-100L. The installed model number should match DOP-107L1-01 exactly. Lite L1 and L2 models have different published panel openings even at the same nominal screen size. The 2026 Delta-issued L1 drawing is available; confirm the installed hardware revision before machining. If an identified feature is not verified in the source notes, leave it open rather than copying a specification from a similarly named device.
Engineering Integration Checklist
For commissioning, first confirm the unit’s actual nameplate and hardware revision. Prepare a supported power supply and grounding scheme, and verify the display orientation and clearance against the correct mechanical drawing. In the HMI project, choose the device and communication driver deliberately, confirm baud rate or IP addressing, and test reading and writing one safe controller tag before connecting wider machine functions. Store a backup of the accepted project and record the firmware and editor versions. Operator controls should be designed as part of the wider machine safeguarding strategy; an ordinary HMI touch button does not replace a certified emergency-stop circuit or a safety controller.
Official Manufacturer Links
Official Manufacturer Product Page Link:
Official Manufacturer Datasheet / Technical Documentation Link:
Additional model-specific distributor information Link:
Similar Products:
• 7 in IPS TFT LCD, 1024 × 600 px
• Resistive Touch input
• 24V DC supply
• RS-232, RS-422, RS-485; Ethernet × 1; USB Host
• MQTT and OPC UA Client (L Type family)
• DIAScreen programming software
• No SD card slot (manufacturer specified)
• IP66 front (manufacturer L1 / family documentation)
• PLC-based machine operation and setpoint entry
• Production equipment status visualization
• Motor drive and automation parameter monitoring
• Operator alarm and event display
• Control panel integration and local maintenance
• Process adjustment with compatible Delta controllers
Need Help Choosing?
Our automation experts are ready to help you select the right product for your application.
- Application Consultation
- Product Selection Support
- Wiring & Integration Help
- After Sales Support
Chat on WhatsApp
+880 1553-346553















Reviews
There are no reviews yet.